<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\NVSStyleSheet.xsl"?>
<Parameter>
<ParameterFamily>media</ParameterFamily>
<LongName>
slipsheet_threshold
</LongName>
<Name>
sst
</Name>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>Trendsetter_VLF_Auto</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Description>
<DescriptionText><text>
This is the threshold set in nvs to distinguish plates from slipsheets. The Picker
slipsheet sensor is an analog reflectivity sensor. Slipsheets reflect higher numbers
than plate emulsions.
</text></DescriptionText>
</Description>
<Type>
uint16
</Type>
<Default>
<UnnumberedList>
<li>0</li>
</UnnumberedList>
</Default>
<Range>
<UnnumberedList>
<li>0 to 850</li>
</UnnumberedList>
</Range>
<ArraySize>
</ArraySize>
<Notes>
<DescriptionText><text>
The value should be set using the actual plate and slipsheet that
the customer is using. Set it half way between what is read when there
is only in the bay and what is read when there is a slipsheet of the right type and colour
on top of a plate in the bay.
</text></DescriptionText>
</Notes>
<Partition>
cal
</Partition>
<SeeAlso>
<UnnumberedList>
<li><Link><LinkAddress>../error_messages/22238.xml</LinkAddress><LinkTitle>Error: E_ALE2_VAL_REMOVE_TABLE_SLIPSHEET</LinkTitle></Link></li>
<li><Link><LinkAddress>../error_messages/22239.xml</LinkAddress><LinkTitle>Error: E_ALE2_VAL_REMOVE_CASS_SLIPSHEET</LinkTitle></Link></li>
<li><Link><LinkAddress>../error_messages/22248.xml</LinkAddress><LinkTitle>Error: E_ALE2_VAL_CASS_UNEXPECTED_SLIPSHEET_DETECTED</LinkTitle></Link></li>
<li><Link><LinkAddress>../error_messages/22277.xml</LinkAddress><LinkTitle>Error: E_ALE2_NO_SS_ON_LOWER_PLATE</LinkTitle></Link></li>
<li><Link><LinkAddress>../commands/picker.xml</LinkAddress><LinkTitle>Command: picker</LinkTitle></Link></li>
<li><Link><LinkAddress>../commands/cal_picker.xml</LinkAddress><LinkTitle>Command: cal picker</LinkTitle></Link></li>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<li><Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link></li>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:37:14 2008 PST
</Updated>
<Links>
</Links>
</Parameter>